PI Control of an Integrating Process
Description| How it worksThis app simulates the step response of a feedback control system consisting of an integrating process and a PI controller.

Download
.xls file (102 KB) or .zip file (25 KB)How to use
The PI controller is specified by the controller gain (C) and the
integral time (TI). The integrating process has only one
parameter T.
Key in values of T, C and TI into the cells B6, B9 and
B10 respectively. The step response is displayed in the chart. The
max time is to be entered into the cells B13.
See this example screen for the step response with the following
inputs:
T = 4
C = 1
TI = 1
Also See:
PID Loop SimulatorBode Plot Generator
Nyquist Plot Generator
PI Control of First Order Process